MIRI GA® is a tabletop device that is designed to perform easy and continuous external gas and temperature validation of IVF incubators. This device can be used to validate different varieties of Esco Medical IVF incubators such as MIRI® Time-lapse Incubator, MIRI® Multiroom Incubator, and Mini MIRI® Incubators.
Features
Get a Quote Download Catalogue Watch VideoThe major advantage of using MIRI® incubators is that the connected MIRI® GA enables the user to have a closed gas system where unnecessary leakage or wastage can be prevented. However, if the incubator used is not an MIRI® incubator, this feature can be used to direct gas to an exhaust if desired.
MIRI® GA comes with a data logging system that could help embryologists to monitor and record each parameter and optionally send email alarms. This software runs a Windows PC (Vista and above), it is not required to install in the MIRI® GA but this feature is very useful for the end-users.
MIRI® GA is a device that can measure temperature and gas concentration simultaneously, making it more efficient than conventional hand-held validating devices that require two separate devices for these measurements.
The MIRI® GA continuously measures gas and temperature 24 hours a day, whereas conventional devices require to measure these parameters at regular intervals.
The suction rate of the MIRI® GA is gentle and adjustable, with a 3 l/h capacity. In contrast, conventional devices can consume up to 12 l/h of gas during operation.
One of the significant advantages of the MIRI® GA is its data logging software, which includes an adjustable alarm threshold not found in other conventional devices.
Lastly, the MIRI® GA can monitor up to six incubation chambers simultaneously, whereas conventional devices can only validate one chamber at a time.
Overall dimensions (W x D x H) | 355 x 360 x 140 mm |
Weight | 8 kg |
Material | Mild steel and aluminum |
Power supply | 115V 60Hz OR 230V 50Hz Medical grade EN60601 approved |
Power consumption | 45 W |
Display | 7 x 16 Segment High visibility LEDs |
6 gas sample ports | Single input or automatic switch. 30 seconds, 1- or 5-minute sample time |
6 PT 1000 sensor inputs | Continual measurement with calibration function. Automatic sensor detection |
Temperature range | 30.0 – 39.9 °C |
CO2 range | 2.8 – 10.0% |
CO2 sensor | NDIR dual beam ± 5.0% of reading or 0.1% CO2 |
O2 range | 2.8 – 20.0% |
O2 sensor | Chemical ± 5.0% of reading or 0.1% O2 |
Flow rate | User set 0-5 l/h |
Alarms | Audible and visible for out-of-range temperature, gas concentration with e-mail option |
Communication | USB port |
MIRI® GA Gas and Temperature Validation Unit | ||
---|---|---|
Item Code | Model Code | Description |
1320045 | MRI-GA | MIRI® GA CO2 / O2 / Temp validation Unit, 115/230V, 50/60Hz |
*Includes data logger software, 1pc PT1000 cable, 1pc Gas connection tube, 1pc Gas feedback tube |
Accessories | ||
---|---|---|
Item Code | Model Code | Description |
1320063 | MRA-1101 | 1pc PT1000 cable |
1320064 | MRA-1102 | Set of 6pcs PT1000 cables |
1320065 | MRA-1103 | 1pc Gas connection tube |
1320066 | MRA-1104 | Set of 6pcs Gas connection tubes |